We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

Despite much progress in electron tomography, quantitative assessment of resolution has remained a problematic issue. The criteria that are used in single particle analysis, based on gauging the consistency between density maps calculated from half data sets, are not directly applicable because of the uniqueness of a tomographic volume. Here, we propose two criteria based on a cross-validation approach. One, called FSC(e/o), is based on a Fourier shell correlation comparison between tomograms calculated from the even and odd members of a tilt series. The other, called noise-compensated leave-one-out (NLOO), is based on Fourier ring correlation comparisons between an original projection and the corresponding reprojection of the tomogram calculated from all the other projections, taking into account the differing noise statistics. Plotted as a function of tilt angle, they allow assessment of the angular dependence of resolution and quality control over the series of projections. Integrated over all projections, the results give a global figure for resolution. Tests on simulated tomograms established consistency between these criteria and the FSC(ref), a correlation coefficient calculated between a known reference structure and the corresponding portion of a tomogram containing that structure. The two criteria-FSC(e/o) and NLOO-are mutually consistent when residual noise is the major resolution-limiting factor. When the size of the tilt increment becomes a significant factor, NLOO provides a more reliable criterion, as expected, although it is computationally intensive. Applicable to entire tomograms or selected structures, NLOO has also been tested on experimental tomographic data.

Original publication

DOI

10.1016/j.jsb.2005.04.006

Type

Journal article

Journal

J Struct Biol

Publication Date

08/2005

Volume

151

Pages

117 - 129

Keywords

Capsid, Computer Simulation, Cryoelectron Microscopy, Electrons, Hepatitis B virus, Mathematics, Models, Theoretical, Reproducibility of Results, Simplexvirus, Tomography